Window’s Impression Technique for Anterior Fibrous Maxillary Ridges
Keywords:
Window’s impression, flabby ridge, selective pressure impression technique, Anterior MaxillaAbstract
This article is aimed at modifying conventional window’s impression technique for making impression of edentulous flabby maxillary ridges. Vinyl Polysiloxane (VPS) impression material was preferred over conventionally used metallic oxide, due to ease of use and dimensional accuracy. The authors used VPS putty consistency on the periphery and regular body for the whole impression. This combination of material consistency gives selective pressure impression. More over the window over the flabby area give the very mucostatic impression of the displaceable area. The authors found the proposed technique superior over Watson’s technique in regards of convenience, time consumption, comfort of the operator and patient.
Downloads
References
Hyde TP, Craddock HL, Blance A, Brunton PA. A cross-over Randomised Controlled Trial of selective pressure impressions for lower complete dentures. J Dent 2010;38:853-8.
Buckley G. Diagnostic factors in the choice of impression materials and Methods. J Prosthet Dent 1955;5:149-61.
Addison PI. Mucostatic impressions. J Amer Dent Assoc 1944;31:941-6.
Fournet SC, Tuller CS. A revolutionary mechanical principle utilised to produce full lower dentures surpassing in stability the best modern upper dentures. J Amer Dent Assoc 1936;23:1028.
Applebaum EM, Rivette HC. Wax base development for complete denture impressions. J Prosthet Dent 1985;53:663-7.
McCord JF, Grant AA. Impression making. Br Dent J 2000;188:484-92.
McGarry TJ, Nimmo A, Skiba JF, Ahlstrom RH, Smith CR, Koumjian JH. Classification system for complete edentulism. The American College of Prosthodontics. J Prosthodont 1999;8:27-39.
Basker RM, Davenport JC. Prosthetic treatment of the edentulous patient. 4th ed. Oxford: Blackwell; 2002.p.172-202.
Allen F. Management of the flabby ridge in complete denture construction. Dent Update 2005;32:524-8.
Kelly E. Changes caused by a mandibular removable partial denture opposing a maxillary complete denture. J Prosthet Dent 1972;27:140-50.
Lytle RB. The management of abused oral tissues in complete denture construction. J Prosthet Dent 1957;7:27-42.
Tan KM, Singer MT, Masri R, Driscoll CF. Modified fluid was impression for severely resorbed edentulous mandiblar ridge. J Prosthet Dent 2009;101:279-82.
Liddelow KP. The prosthetic treatment of the elderly. Br Dent J 1964;117:392-4.
Osborne J. Two impression methods for mobile fibrous ridges. Br Dent J 1964;117:392-4.
Watson RM. Impression technique for maxillary fibrous ridge. Br Dent J 1970;128:552.
Watt DM, MacGregor A. Designing complete dentures. 2nd ed. Bristol: IOP Publishing ; 1986.p.24-5.
Lynch CD, Allen PF. Management of the flabby ridge: re-visiting the principles of complete denture construction. Eur J Prosthet Rest Dent 2003;11:145-8.
Lynch CD, Allen PF. Quality of written prescriptions and master impression for fixed and removable prosthodontics: a comparative study. British Dent J 2005;198:17-20.
Lynch CD, Allen PF. Quality of communication between dental practitioners and dental technicians for fixed prosthodontics in Ireland. J Oral Rehab 2005;32:901-5.
Woelfel JB. Contour variations in impressions of one edentulous patient. J Prosthet Dent 1962;12:229-54.
Freeman SP. Impressions for complete dentures. J Am Dent Assoc 1969;73:1173-8.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Syed Murtaza Raza Kazmi, Sameer Qureshi
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Articles published in the Journal of Dow University of Health Sciences are distributed under the terms of the Creative Commons Attribution Non-Commercial License https://creativecommons.org/ licenses/by-nc/4.0/. This license permits use, distribution and reproduction in any medium; provided the original work is properly cited and initial publication in this journal.